ACA-20RM Series
True-RMS-AC Ammeters with Built-in CT
PANEL INSTALLATIONS
All connections to ACA-20RM Series ammeters must be made after the
ammeter is securely attached to its panel and with all associated load
and supply voltages de-energized (off). However, using extreme caution
and observing all safety measures applicable to the user’s installation,
50A split-core CT models can be connected to energized current-carrying
load conductors, but connections to TB1 must always be made with the
ammeter’s power source off.
Care should be exercised when passing the load-carrying conductor
through the meter’s built-in CT—particularly when larger conductors are
used. The installed wire-positions should be such that minimal mechani-
cal forces are applied to the built-in CT, TB1, or to the ammeter itself. In
Using Figure 4 as a guide, carefully insert the bezel/color ?lter assembly
into the panel opening. From the rear of the panel, install the four round
plastic standoffs over the bezel’s threaded studs. Install the pc-board
assembly; then attach and securely tighten each of the four hex nuts
to 15-20 ozf-in (0.106 to 0.140 N-m). Use only the factory-supplied
hardware as the use of substitute hardware could result in an unsafe
installation and/or adversely affect the reliability of the ammeter itself.
The recommended range of panel thickness that can be used with the
supplied hardware is 0.040 inches (1.0mm) to 0.125 inches (3.2mm).
Panel thickness outside of this range will require additional user-supplied
hardware and/or modi?cations.
high-vibration environments, it is strongly recommended that adequate
strain reliefs be used for all load and supply wiring.
PANEL
Figure 4. Panel Installation
BEZEL AND PANEL CUTOUT
RECOMMENDED DRILL AND
0.187
PANEL CUTOUT DIMENSIONS
FRONT VIEW
(4.75)
1.280
(32.51)
0.69
(17.5)
1.07
(27.18)
INTERNAL CORNER RADII:
0.032 (0.81) MAX.
0.116 (2.95)
0.838
(21.29)
1.826 (46.38)
1.336 (33.93)
1.626 (41.30)
0.093 (2.362) DIAMETER (4 REQUIRED)
www.murata-ps.com/dpm
0.145 (3.68)
email: sales@murata-ps.com
MPM_ACA-20RM_B08 Page 4 of 5
相关PDF资料
ACA-20RM-5-AC3-RL-ALM-C AMMETER AC 30A 120V W/ALARM RED
ACA5-20PC-1-AC1-RL-C AMMETER LED 85-264VAC 50A RED
ACA5-20RM-5-AC3-RL-C AMMETER AC 200A 120VAC RED
ACB120DHNN CONN EDGECARD 240PS .050 DIP SLD
ACB92DHHR-S378 CONN EDGECARD 184PS PCI64 5V
ACC70DKSH-S1191 CONN EDGECARD 140PS .100 DIP SLD
ACC70DRSN-S273 CONN EDGECARD 140PS DIP .100 SLD
ACM20-4-AC1-R-F-C METER AC POWER 100A W/FREQ READ
相关代理商/技术参数
ACA-20RM-4-AC4-RL 制造商:Murata Power Solutions 功能描述:True-RMS-AC Ammeters With Built-In CT
ACA-20RM-4-AC4-RL-ALM-C 功能描述:数字面板表 50A rng, 170-264Vac 3.5 Dig brght rd LED RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
ACA-20RM-4-AC4-RL-C 功能描述:数字面板表 50AInput TrueRMS-AC RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
ACA-20RM-5-AC3-RL-ALM-C 功能描述:数字面板表 30A rng, 85-140Vac 3.5 Dig brght rd LED RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
ACA-20RM-5-AC3-RL-C 功能描述:数字面板表 30AInput TrueRMS-AC RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
ACA-20RM-5-AC4-RL-ALM-C 功能描述:数字面板表 30A rng, 170-264Vac 3.5 Dig brght rd LED RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
ACA-20RM-5-AC4-RL-C 功能描述:数字面板表 30AInput TrueRMS-AC RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
ACA-20RM-ALM 制造商:MURATA-PS 制造商全称:Murata Power Solutions Inc. 功能描述:True-rms-AC Ammeters with Alarm Function